DS200TBQCG1A provides field terminations for 4–20 mA inputs, LVDT/R position feedback and configurable milliamp outputs in the GE Mark V LM turbine control system.

PRODUCT TYPEANALOG I/O TERMINATION MODULE
PLATFORMMark V LM
CURRENT IN4–20 mA
OUTPUT MAX20/200 mA
MANUFACTURERGE
CONDITION / WARRANTYOriginal New · One-Year Warranty
ISO CERTIFICATIONISO-Certified Product
VERIFICATION● Product photos and videos provided after inquiry
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
GE ● ANALOG I/O TERMINATION MODULE
Mark V LM

DS200TBQCG1A

ANALOG I/O TERMINATION MODULE

MARK V LM · ANALOG I/O TERMINATION MODULE

MODULE ROLE
DS200TBQCG1A connects analog current and position-feedback field wiring to the TCQA I/O board through separate JBR and JFR signal paths.
LONG DESCRIPTION
DS200TBQCG1A routes 4–20 mA inputs and milliamp outputs through JBR, while JFR carries LVDT/R position-feedback inputs to TCQA. The field terminations occupy analog-core position 9 in the documented Mark V LM arrangement. BJ1–BJ15 provide the current-input DCOM connections; BJ16 and BJ17 select the output-current limit. The associated TCQA electronics perform signal conditioning, so the termination board and the processor-board configuration work together.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
ORDER NUMBER BREAKDOWN

How the DS200TBQCG1A Reference Is Structured

DS
ManufacturerGE, Salem, Virginia
200
Assembly levelBase-level board
TBQC
Functional acronymanalog i/o termination module
G1
Group variationGroup 1
A
Functional revisionFirst functional revision A
MANUFACTURER-REFERENCE CHARACTERISTICS

Technical Specifications

GE Mark V LM ↗
DS200TBQCG1A ANALOG I/O TERMINATION MODULE

Engineering data at a glance

Click “+” to expand more specifications.

CURRENT IN4–20 mA
OUTPUT MAX20/200 mA
FEEDBACKLVDT/R
LOCATION9
Engineering functions and interfaces follow the referenced manufacturer documentation.
Configuration note Match the complete assemblyDS200TBQCG1A, installed system interfaces and application-specific configuration.
GENERAL INFORMATION −
BrandGE
Part numberDS200TBQCG1A
Product typeAnalog I/O Termination Module
Current inputs4–20 mA
Position inputsLVDT/R
Core position9
SIGNAL CONNECTIONS +
JBRCurrent inputs and milliamp outputs between TBQC and TCQA
JFRLVDT/R position-feedback inputs to TCQA
JBS/T, JFS/T, TEST.Typically not used
HARDWARE JUMPERS +
BJ1–BJ15Connect the current-input negative terminals to DCOM
BJ16 / BJ17Select the 20 mA or 200 mA output-current limit
Input processingProvided by the associated TCQA I/O electronics
FUNCTIONAL CONTEXT +
System role: TBQC provides the wiring terminations for analog inputs and outputs. Current-loop signals use JBR; LVDT/R position feedback uses JFR. Hardware jumper positions determine the current-input reference and output-current limit.
Source:GEH-6153, Chapter 4 pages 4-41–4-42 and Appendix A, TBQC
FAQ

Questions Buyers Ask Most

What does DS200TBQCG1A terminate?+

DS200TBQCG1A terminates 4–20 mA inputs, LVDT/R position inputs and milliamp outputs for the Mark V LM analog I/O system. These signal paths connect to the associated TCQA board.

Which connector carries current signals on DS200TBQCG1A?+

DS200TBQCG1A uses JBR for current inputs and milliamp outputs exchanged with TCQA. LVDT/R position feedback follows the separate JFR connector path.

How does DS200TBQCG1A connect LVDT/R feedback?+

DS200TBQCG1A routes LVDT/R position-feedback inputs through JFR to the TCQA board. The termination board provides field connections while the I/O electronics process the feedback.

What do BJ16 and BJ17 select on DS200TBQCG1A?+

DS200TBQCG1A uses BJ16 and BJ17 to select a 20 mA or 200 mA maximum output-current configuration. The selected hardware setting must match the connected current-loop application.

What is the purpose of BJ1–BJ15 on DS200TBQCG1A?+

DS200TBQCG1A uses BJ1–BJ15 to connect the negative side of the corresponding current inputs to DCOM. The required grounding configuration depends on the field circuit and the installed system design.

Where is DS200TBQCG1A located in the documented core arrangement?+

DS200TBQCG1A is the TBQC termination board in analog-core position 9 in GEH-6153. Its ribbon-cable interfaces connect the field terminations to the associated TCQA board.

CONTACT PRODUCT SPECIALIST

Check your configuration with Frida

Share the complete order number and application details for compatibility, availability and lead-time checking.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Product Information for
DS200TBQCG1A

Official manufacturer-documentation status for GE DS200TBQCG1A.

Official datasheet status

No current official DS200TBQCG1A product datasheet was located in the manufacturer's public documentation. For product documentation and compatibility details, please contact Product Specialist Frida.

CONTACT FRIDA

Contact to Get Support

Send the complete model, quantity, and your technical or purchasing question.

No working manufacturer-hosted instruction or datasheet PDF was confirmed; contact Frida for the applicable document.

GE MARK V LM SYSTEM RELATIONSHIP

How DS200TBQCG1A Fits Mark V LM

GE is the manufacturer brand; GE Mark V LM is the product family; and DS200TBQCG1A is the analog i/o termination module.

GE · BRAND
GE Mark V LMAnalog I/O Termination Module
SYSTEM ROLE

Current In

connects analog current and position-feedback field wiring to the TCQA I/O board through separate JBR and JFR signal paths.

MODULE / CONFIGURATION

Signal Connections

Current inputs and milliamp outputs between TBQC and TCQA

ASSEMBLY FORMAT

DS200TBQCG1A · TBQC Board

GE Mark V LM analog i/o termination module.

System relationship: connects analog current and position-feedback field wiring to the TCQA I/O board through separate JBR and JFR signal paths.
APPLICATION AREAS

Application map for DS200TBQCG1A

Current-Loop InputsTerminate 4–20 mA field-transducer signals
Position FeedbackConnect LVDT/R field feedback to TCQA
Mark V LM DS200TBQCG1A DS200TBQCG1A · Analog I/O Termination Module
Milliamp OutputsProvide the configured current-output termination path
Analog-Core InterfacesSeparate current-loop and LVDT/R ribbon-cable signal paths
ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
Same-brand recommendations

GE Related Models

GE ↗PACSystems and Field Control models
Customers Also Source from Moore

Hot-selling Models

Select a brand to view models
OTHER BRANDSSelected automation and instrumentation models
ROSEMOUNT3051CG3APressure Transmitter
ROSEMOUNT3051CG4A22APressure Transmitter
ENDRESS+HAUSERCLD18Conductivity Measuring System
ENDRESS+HAUSERCLS15-A1A1AConductivity Sensor
ENDRESS+HAUSERCLS50D-AA2C21Conductivity Sensor
ENDRESS+HAUSERCLS54Conductivity Sensor
ENDRESS+HAUSERCOS61D-1020/0Dissolved Oxygen Sensor
ENDRESS+HAUSERCPM253-CP00015pH/ORP Transmitter
ACCUENERGYIIR-M-RCT-P1Power and Energy Meter
OMRONCJ1W-DA021Analog Output Unit
OMRONCJ1W-DA041Analog Output Unit
OMRONCJ1W-ID261Digital Input Unit
Deixe um recado
Se você está interessado em nossos produtos e deseja saber mais detalhes, deixe uma mensagem aqui, responderemos o mais breve possível.
  • CLP
  • DCS
  • ETI
  • HMIS
produtos relacionados